THIS PRODUCT IS NO LONGER AVAILABLE The CHECK-IT Model 0616 Steam Trap Tester allows you to accurately and quickly measure pipe temperatures at the upstream and downstream sides of a steam trap. Armed with such accurate readings, you can instantly determine whether or not a steam trap is malfunctioning.
With a temperature range of -100°F to 1999°F, this pocket size tester comes in a self-containing high impact case holding a quick response CHECK-IT 04260276 surface probe and a 9 volt battery.
The CHECK-IT 0616 Digital Steam Trap Tester is easy to read since it incorporates a large .5" liquid crystal display which is updated 1.5 times per second.
Remember . . . when a steam trap malfunctions, overall system efficiency decreases and escaping steam produces energy loss.
Includes the 04260276 Surface Probe.
SPECIFICATION DATA
|
FEATURES
- Built for Reliability
- Designed especially for Steam Trap Testing
- Readings instantaneous - NO DELAY
- Detects malfunctioning traps instantly
- Stainless Steel probe with 3 ft. retractable cord, for hard-to-reach areas
- Conveniently packaged for all field use
- ON/OFF switch recessed - No accidental turn on to waste batteries!
- Super sensitive probe responds instantly to the hottest or coldest temperatures
- Operates on one 9V battery, 1 year life in normal use
- Increases efficiency and decreases energy loss
- Large 0.5 inch LCD display: read-out visible even in direct sunlight
- Open probe indication
- Low battery indication
- One full year warranty
- Made in the United States of America
|
SPECIFICATIONS
- Range:
- -100° to 1999°F
- Accuracy:
- -100° to 1000°F, ±1°
- Rsolution:
- 1°F
- Repeatability:
- 1°F
- Operating temperature:
- -10° to 55°C ambient
- Power:
- One 9V battery, Approximately 1000 hours life
- Sensor:
- Type K thermocouple
- Probes:
- Usable to 1999°F Intermittent, 1200°F Continuous
- Chord
-
- Retractable 9 inches extends to 3 ft.
- Connector:
- Phono Type
- Warranty:
- One full year
- Storage Temperature:
- -20°C to 60°C at 40% relative humidity
- Size:
- 7-1/4" x 3-5/8" x 1-1/8"
- Weight:
- (including battery) Approximately 10 ounces
- Display:
- 0.5" high liquid crystal (LCD)
- Case:
- Drop-proof molded case
|
READINGS CHART
The table shows that for an upstream pressure of 150 psig, a pyrometer reading between 329°F and 348°F should be obtained. And for a down stream steam pressure of 15 psig, a pyrometer reading of between 225°F and 238°F is desirable. We can conclude, therefore, that the trap is functioning properly.
PIPE SURFACE TEMPERATURE vs. STEAM PRESSURE
Steam Pressure (PSIG) | Steam Temp. (°F) | Pipe Surface Temp. (°F) |
15 | 250 | 225-238 |
50 | 298 | 268-283 |
100 | 338 | 304-321 |
150 | 366 | 329-348 |
200 | 388 | 349-369 |
450 | 460 | 414-437 |
|
|
Check-It Electronics
235 Main Street,Suite 281, Madison, N.J. 07940
Call: 908-354-8236 • Fax: 908-354-9564
|
|