Click to enlarge

CHECK-IT 0616  Digital Steam Trap Tester Set

Click here for a
technical drawing
of this product
The CHECK-IT Model 0616 Steam Trap Tester allows you to accurately and quickly measure pipe temperatures at the upstream and downstream sides of a steam trap. Armed with such accurate readings, you can instantly determine whether or not a steam trap is malfunctioning. With a temperature range of -100F to 1999F, this pocket size tester comes in a self-containing high impact case holding a quick response CHECK-IT 04260276 surface probe and a 9 volt battery. The CHECK-IT 0616 Digital Steam Trap Tester is easy to read since it incorporates a large .5" liquid crystal display which is updated 1.5 times per second. Remember . . . when a steam trap malfunctions, overall system efficiency decreases and escaping steam produces energy loss. Includes the 04260276 Surface Probe.

SPECIFICATION DATA

FEATURES

  • Built for Reliability
  • Designed especially for Steam Trap Testing
  • Readings instantaneous - NO DELAY
  • Detects malfunctioning traps instantly
  • Stainless Steel probe with 3 ft. retractable cord, for hard-to-reach areas
  • Conveniently packaged for all field use
  • ON/OFF switch recessed - No accidental turn on to waste batteries!
  • Super sensitive probe responds instantly to the hottest or coldest temperatures
  • Operates on one 9V battery, 1 year life in normal use
  • Increases efficiency and decreases energy loss
  • Large 0.5 inch LCD display: read-out visible even in direct sunlight
  • Open probe indication
  • Low battery indication
  • One full year warranty
  • Made in the United States of America

SPECIFICATIONS

Range:
-100 to 1999F
Accuracy:
-100 to 1000F, 1
Rsolution:
1F
Repeatability:
1F
Operating temperature:
-10 to 55C ambient
Power:
One 9V battery, Approximately 1000 hours life
Sensor:
Type K thermocouple
Probes:
Usable to 1999F Intermittent, 1200F Continuous
Chord
Retractable 9 inches extends to 3 ft.
Connector:
Phono Type
Warranty:
One full year
Storage Temperature:
-20C to 60C at 40% relative humidity
Size:
7-1/4" x 3-5/8" x 1-1/8"
Weight:
(including battery) Approximately 10 ounces
Display:
0.5" high liquid crystal (LCD)
Case:
Drop-proof molded case

READINGS CHART

The table shows that for an upstream pressure of 150 psig, a pyrometer reading between 329F and 348F should be obtained. And for a down stream steam pressure of 15 psig, a pyrometer reading of between 225F and 238F is desirable. We can conclude, therefore, that the trap is functioning properly.


PIPE SURFACE TEMPERATURE vs. STEAM PRESSURE
Steam Pressure
(PSIG)
Steam Temp.
(F)
Pipe Surface Temp.
(F)
15
250
225-238
50
298
268-283
100
338
304-321
150
366
329-348
200
388
349-369
450
460
414-437



CHECK-IT 0616 SET$207.08

Surface Probe
CHECK-IT 04260276$115.47
Certification to NIST
CHECK-IT 1918$30.00





Check-It Electronics
235 Main Street,Suite 281, Madison, N.J. 07940


Call: 908-354-8236 Fax: 908-354-9564